Emergency Operation - How to bypass Frequency converter connection for a #reefer #Container of #starcool.


Emergency Operation - How to bypass Frequency converter connection for a #reefer #Container of #starcool.



If FC is defective and no replacement part is available, the compressor may be run in the on / off mode.

Defective FC is dismounted and the 3 phases are directly applied to the compressor supply terminals.

Also, a wire-jumper has to be fitted on the remaining 3 terminals, see below figure.

In the service menu, F03 FC TYPE, the parameter NONE is selected. The Unit will then run in the on / off mode with deteriorated temperature controlling performance.

The connection for the FC is shown on below drawings:



Complete step by step pictorial procedure of bypass.